Digitrax Driver Download



PR3 / PR4 Windows XP, Vista, 7, and 8 Drivers.Return to Downloads. PR3 / PR4 Windows XP, Vista, 7, and 8 Drivers. DigiTrax Entertainment is a global music company dedicated to bringing the best interactive music services to market.

Digitrax LocoNetĀ®

  • Command Stations
  • Programmers & Adapters
  • Networking
  • Technical

Supported Hardware

Devices, command stations, networks, and protocols:

Digitrax Software

  • WiFi Throttles

Applications

By the community of JMRI.org:

Tools

JMRI tools for working with your layout:
  • Common Tools:
  • Blocks:
  • Routing and Control:
  • Other:

Layout Automation

Driver
Use JMRI to automate parts of your layout and operations:

JMRI Help:
Contents/ Index
Glossary/ FAQ

  • Connecting JMRI to a Digitrax DCS240
    • Choosing the configuration method
      • DCS240 USB interface as a stand-alone decoder programmer
      • DCS240 USB interface as a LocoNet Interface

Digitrax Driver Download App

Driver

JMRI may be connected to the Digitrax DCS240 in any of a wide variety of ways. Since the DCS240 has a built-in USB interface, it is possible to simply plug a USB cable into the computer and the DCS240, and configure JMRI to suit this connection. It is also possible to use another LocoNet interface device, such as a LocoBuffer-USB, Digitrax PR3, or Digitrax PR4, to interface a computer to LocoNet, and connect that LocoNet to the DCS240. JMRI does not prefer any one connection method over any other method. Choose one which is suitable for your needs.

If a USB cable is used to connect the JMRI computer to the DCS240's USB connection, JMRI may be configured in one of two modes. If the computer will only be used for decoder programming, and JMRI will not need access to LocoNet features other than the DCS240 'programming track', then JMRI may be configured to use a 'connection' where the DCS240 USB interface is placed into a mode where it acts as a standalone decoder programmer. In this mode, JMRI will access the DCS240 dedicated programming track connections. This mimics the 'standalone programmer' configuration which the PR2 provides, and which the PR3 and PR4 can support.

Alternately, when JMRI will be used to access LocoNet resources which go beyond simply the DCS240 programming track, then JMRI should be configured to act as a general-purpose LocoNet interface. The JMRI 'connection' should be configured so that the 'command station' type specifies the type of command station which is being used.

Digitrax Driver Download Software

If, instead of using the DCS240's integrated USB port, you plan to connect your computer to the DCS240 using a LocoNet adapter device, follow the instructions found here.

The table below summarizes these possibilities.

Connection TypeUsageSettings in JMRI Connection ProfileInstructionsAvailable JMRI Capabilities
System ConnectionJMRI Command Station Type
USB cable from computer to DCS240 USB connectorDecoder Programming'DCS240 USB Interface''DCS240 Standalone Programmer'Configuration helpProgram decoder CVs on the dedicated programming track
Operate one loco on the dedicated programming track
LocoNet Interface, Decoder Programming'DCS240 USB Interface''DCS240 (Advanced Command Station)'Configuration helpProgram decoder CVs on the dedicated programming track and/or the main track
Control one or more locos on the main track
Control and monitor LocoNet-connected Switches, Sensors, and Transponding
Configure some LocoNet devices
Control or monitor the LocoNet Fast Clock
Update firmware on some LocoNet devices
etc.
LocoNet Interface, Decoder ProgrammingComputer Connection to something other than the DCS240 USB connectorSomething other than 'DCS240 USB Interface''DCS240 (Advanced Command Station)'Configuration helpProgram decoder CVs on the dedicated programming track
Control one or more locos on the main track
Control and monitor LocoNet-connected Switches, Sensors, and Transponding
Configure some LocoNet devices
Control or monitor the LocoNet Fast Clock
Update firmware on some LocoNet devices
etc.

Note that it is possible to use the DCS240 in a 'booster' mode, and rely upon some other command station. If this configuration is used, the 'command station' specified for the JMRI connection should match the device which is actually acting as the command station.

Choosing the configuration method

When setting up a JMRI 'connection profile', which 'command station' should you use when configuring JMRI? That depends on what you intend to do with JMRI.

Digitrax Downloads

  • If you will only use JMRI to program decoders on the dedicated programming track, then configuring the connection for the 'command station' type of 'DCS240 Standalone Programmer' mode is a good choice. In this mode, JMRI will be able to read and write decoder CV values. In this mode, you may also use a JMRI throttle to select and control the locomotive on the dedicated programming track, subject to the ability of the DCS240 to supply sufficient current to the decoder. JMRI will not be able to access LocoNet peripherals and JMRI throttles will not be able to control decoders via the 'main track'.
  • If you wish JMRI to be able to control decoders via the DCS240 main track outputs, and access LocoNet devices, then configuring the connection for the 'command station' type of 'DCS240 USB Interface' mode is a good choice. In this mode, JMRI is able to control decoders connected via the main track outputs and access LocoNet devices. JMRI may also perform decoder programming via the dedicated programming track, but JMRI throttles will not be able to run decoders which are on the dedicated programming track.

  • If you think that both modes may be useful to you, you should consider setting up two configuration profiles. Then, when you start JMRI, you may select the configuration profile which suits the way you want to use JMRI. And to switch to the other mode, you may simply quit JMRI and re-start it, and select the other profile, so that you may perform the other type of work.

DCS240 USB interface as a stand-alone decoder programmer

When the DCS240 USB interface is configured to act as a programmer, it acts upon the dedicated programming track via the 'programming track' connections on the DCS240. When JMRI is properly configured, JMRI can use the DCS240 programming track to access decoder CVs when the decoder is connected to the programming track.

This JMRI configuration may also be used to download sound information into Digitrax sound decoders and, within its limited current capability, run one locomotive to test it. When used with Digitrax SFX decoders, 'neutral mode' allows you to vary the speed without the motor moving the decoder, so you can hear how the locomotive sound reacts to varying speeds.

In this mode of operations, JMRI will not have access to LocoNet-based devices.

Setup for the DCS240 acting as a standalone programmer

To use the DCS240 programming track, connect the DCS240 to its power supply and connect a dedicated piece of track which you'll use as the programming track to the DCS240 'programming track' terminals. Finally, connect a USB cable between the DCS240 and your computer.

To set up JMRI to use the DCS240 via the dedicated decoder programming track mode:

  • Start the program.
  • Open the Preferences window from the Edit menu and configure the connection by:
    • For the 'System Connection' setting, select 'DCS240 USB Interface'
    • Under 'Serial Port', select the serial port that's connected to the DCS240
    • In the 'Command station type' option, select the type of command station you've got on your LocoNet. Typically, this will be 'DCS240 USB Interface as standalone programmer'.
    • In the advanced settings, the speed will be fixed at 57,600 baud.
    • In the advanced settings, the 'Flow Control' option defaults to 'Use Hardware Flow Control', which is the preferred setting for the DCS240. You should try that first, as it is the most reliable mode. Only if you can't reliably program decoders using that choice, and only after checking that you're using the right port, should you select 'None' for this preference and try again.
  • Click Save at the bottom of the preferences window, quit the program and restart.

The 'connection' preferences should look similar to this image:

DCS240 USB Interface in Standalone Programming Mode Usage Hints

  • You can use a JMRI throttle to control the locomotive connected to the DCS240 Programmer track. Use the JMRI Power Control or the 'Power' menu item on the Throttle's menu bar to turn on track power, and then you can operate the locomotive normally via a JMRI throttle.
  • The DCS240 can only provide very limited current to the programming track, so Digitrax has built a 'neutral mode' into their sound decoders. When JMRI and the DCS240 is running a Digitrax sound decoder, the motor is disconnected to reduce the current load. You can still ramp the speed up and down with the throttle and listen to how the sound responds, but the motor won't move the locomotive.
    • To implement that 'neutral mode' described above, the DCS240 automatically writes CV128 to 0 or 1. This happens when a JMRI throttle is used to run the locomotive on the DCS240 programming track, and there's nothing JMRI can do to prevent it. Unfortunately, this can interfere with the CV programming on some non-Digitrax decoders. For example, it will set the 'Master Volume' CV128 on some SoundTraxx decoders to a very low volume.
    • If you are working with a decoder that uses CV128 for something, you should either not use a JMRI throttle to run the locomotive on the DCS240 programming track, or remember to rewrite CV128 with the right value just before removing the locomotive from the track.
  • Other decoders, including decoders from other manufacturers, may draw enough motor current to trip the DCS240 internal circuit breakers. This will cause JMRI to mark track power as 'off'. Just wait a couple seconds and turn the track power back on to recover.
  • It is possible run trains via LocoNet-based throttles when JMRI is programming a decoder on the DCS240 programming track.

DCS240 USB interface as a LocoNet Interface

When acting as an interface, the DCS240 USB connection allows JMRI to interact with devices connected to LocoNet. This includes programming decoders on a programming track attached to a LocoNet command station. Where the LocoNet command station supports 'programming on the main', JMRI is able to make use of that feature.

Setup for the DCS240 acting as a LocoNet interface

To use the DCS240 USB connection as a LocoNet interface, connect a LocoNet cable to a LocoNet connector on the DCS240. Connect an appropriate power supply to the DCS240, per the Digitrax instructions for the DCS240. The DCS240 USB interface will not be able to communicate with LocoNet unless the DCS240 is properly powered. Finally, connect an appropriate USB cable between the DCS240 USB connector and your computer.

To set up a JMRI application to use the DCS240 as an interface to a LocoNet which includes a LocoNet command station:

  • Start the program.
  • Open the Preferences window from the Edit menu and configure the connection by:
    • For the 'System Connection' setting, select 'DCS240 USB Interface'
    • Under 'Serial Port', select the serial port that's connected to the DCS240
    • In the 'Command station type' option, select the type of command station you've got on your LocoNet. Typically, this will be 'DCS240 (Advanced)', but, if you have configured your DCS240 to act only as a booster, you should select the command station option which matches the active command station.
    • In the advanced settings, the speed will be fixed at 57,600 baud.
    • In the advanced settings, the 'Flow Control' option defaults to 'Use Hardware Flow Control', which is the preferred setting for the DCS240. You should try that first, as it is the most reliable mode. Only if you can't reliably program decoders using that choice, and only after checking that you're using the right port, should you select 'None' for this preference and try again.
  • Click Save at the bottom of the preferences window, quit the program and restart.

Digitrax Driver Download Windows 7

The 'connection' preferences should look similar to this image:

DCS240 connected via some other LocoNet Interface

Digitrax Driver Download Windows 10

JMRI may connect to the LocoNet via a LocoNet interface other than the DCS24 USB connector. When connected in this fashion, these general instructions, or, where available, the JMRI documentation associated with the LocoNet interface which is being used.

DCS240 Drivers

The DCS240 USB interface needs to have a driver installed when used with any Microsoft Windows Operating System. See the Digitrax 'Downloads' page for drivers. At the time this help page was written, Digitrax provides Windows drivers for the PR3 device. Those drivers are suitable for use with the DCS240 USB interface. Make sure to follow any instructions, particularly any instructions about the order of installing the drivers and plugging in the device.

You don't need to install a separate driver when using current versions of Mac OS X or Linux.

Digitrax Dcs210

  • The JMRI Rosters page.
  • The JMRI Command Station Configuration page describes how to configure command station OpSw settings.
  • For more information on the DCS240 itself, please consult the Digitrax web site:
    • The Digitrax DCS240 product page.
    • The Digitrax DCS240 Support page.
    • Drivers for Windows-based machines may be found at the Digitrax Downloads page. Note: Use the Digitrax PR3 drivers when connecting via the DCS240 USB interface.

LocoNetĀ® is a registered trademark of Digitrax, Inc.